Precision Ducting, Smart HVAC & Seamless MEP Execution. (Delivering across Pakistan).

Contact us

Precision Ducting, Smart HVAC & Seamless MEP Execution. (Delivering across Pakistan).

Precision Ducting, Smart HVAC & Seamless MEP Execution. (Delivering across Pakistan).

product

Euroklimat Air Handling Unit (Cooling Capacity 2980 kW) 848 TON

Euroklimat Air Handling Unit (Cooling Capacity 2980 kW) 848 TON

  • Massive air volume 
  • High cooling capacity 
  • Call/Whatsapp 0306-4410583 
  • Thermal bridge‑free casing 
  • Aluminum alloy outer frame 
  • Excellent thermal insulation 
  • High‑performance heat exchanger
  • Advanced filtration system 
  • Low leakage design 
  • Professional selection software
  • Intelligent control 

Description

Euroklimat EKDM 3060 Air Handling Unit: 848 TR for Mega Projects

Moving 300,000 cubic meters of conditioned air every hour is not a job for an ordinary unit. Airports, hospitals, pharmaceutical plants, and giant malls need equipment that can handle huge loads, keep air clean, and run around the clock without failing. The Euroklimat EKDM 3060 Air Handling Unit is built for exactly that scale.

This guide is for MEP engineers, consultants, contractors, facility managers, and project owners. It explains what this modular AHU is, how it performs, and where it fits best. You’ll also find a full specification table, a performance comparison, common specification mistakes, and answers to the questions buyers ask most often. By the end, you’ll know whether the EKDM 3060 is the right fit for your project and how to source it with confidence.

What Is the Euroklimat EKDM 3060 Air Handling Unit?

The EKDM 3060 is a mega-capacity, modular air handling unit designed for industrial, healthcare, and commercial projects that need extremely high air volumes and strict air quality control. It delivers a rated airflow of 300,000 m³/h and a cooling capacity of 2980 kW, which equals roughly 10,170,000 BTU/hr or about 848 tons of refrigeration (TR).

This Euroklimat Air Handling Unit combines a thermal bridge-free casing, advanced multi-stage filtration, energy-efficient twin fans, and a Super Exhaust function in one engineered package. It is an Industrial Air Handling Unit in the truest sense. It is built for continuous heavy-duty operation, not occasional comfort cooling.

Its modular design lets engineers configure sections for cooling, heating, humidification, and filtration. The unit can be shaped around the needs of a cleanroom, an operating theater suite, or a metro concourse.

Key Facts at a Glance

  • Model: EKDM 3060
  • Cooling capacity: 2980 kW (≈ 10,170,000 BTU/hr, ≈ 848 TR)
  • Rated air volume: 300,000 m³/h
  • Certifications: AHRI and EUROVENT certified
  • Special function: Super Exhaust
  • Construction: Modular, thermal bridge-free casing with an aluminum alloy frame
  • Best for: Hospitals, OTs, pharma plants, airports, metro stations, industrial facilities, malls, hotels, and mega offices

Technical Specifications of the 2980 kW Air Handling Unit

The table below lists the core engineering data for the EKDM 3060. Use it as a reference during load calculations, plant room planning, and equipment schedules.

Parameter

Details

Model

EKDM 3060

Rated Air Volume

300,000 m³/h

Air Volume Range

225,909 – 280,000 m³/h

Coil Frontal Area

27.89 m²

Fan Impeller Diameter

1400 × 2 mm

Max Fan Total Pressure

2000 Pa

Max Motor Power

110 × 2 kW (220 kW total)

Cooling Capacity

2980 kW

Cooling Capacity in BTU/hr

2980 × 3412 ≈ 10,170,000 BTU/hr

Tonnage Equivalent

~848 TR

Water Flow Rate

65 – 84.5 L/s

Pipe Diameter

DN 80

Insulation Thermal Conductivity

0.0188 W/m·K (polyurethane foam)

Coil Test Pressure

Up to 1.6 MPa

Casing Leakage Rate

0.02% at −1000 Pa

Certifications

AHRI and EUROVENT

How to Read These Numbers

Cooling capacity in kilowatts converts to BTU/hr by multiplying by about 3,412. To get tons of refrigeration, divide BTU/hr by 12,000. For the EKDM 3060, that math gives roughly 848 TR.

The twin 1400 mm fan impellers, each driven by a motor of up to 110 kW, produce up to 2000 Pa of total pressure. That pressure lets the unit push air through long duct runs, high-grade filters, and complex distribution networks without losing performance. The chilled water range of 65 to 84.5 L/s through DN 80 connections helps engineers size pumps and piping early in the design stage.

Takeaway: These figures place the EKDM 3060 firmly in the mega-project category. It can replace several smaller units in one coordinated system.

Key Features of This Euroklimat Air Handling Unit

Every component of the EKDM 3060 is chosen for reliability under heavy loads. Here’s what sets it apart.

Thermal Bridge-Free Casing and Aluminum Alloy Frame

The casing is engineered to remove thermal bridges, the weak points where heat and cold travel through metal. This prevents condensation on the outer panels, reduces leakage, and protects the surrounding plant room. The aluminum alloy outer frame stays strong and stable, so it resists deformation even at full fan pressure.

Excellent Thermal Insulation

Panels use polyurethane foam with a very low thermal conductivity of 0.0188 W/m·K. In practice, less energy escapes through the casing walls. Supply air stays at the designed temperature from coil to duct.

High-Performance Heat Exchanger

The cooling coils use copper tubes with rust-resistant fins. Each coil is pressure tested up to 1.6 MPa. The result is efficient heat transfer, long coil life, and dependable performance in humid or demanding climates.

Advanced Filtration and Low Leakage Design

Air passes through pleated primary filters and medium-efficiency bag filters as standard. HEPA filtration is available as an option for cleanrooms and surgical spaces. A casing leakage rate of only 0.02% at −1000 Pa keeps unfiltered air from slipping past the filters. That protection matters a great deal in sterile environments.

Super Exhaust Function and Intelligent Control

The Super Exhaust function adds dedicated exhaust capability. It helps remove stale or contaminated air and supports pressure balance between spaces. This is especially useful where rooms must stay at positive or negative pressure, such as operating theaters, isolation wards, and production areas.

The unit also supports sensors, actuators, and building automation integration. Operators can monitor temperature, humidity, pressure, and filter status in real time.

Professional Selection Software

Euroklimat’s proprietary selection software sizes each unit against actual project conditions. This reduces the risk of oversizing or undersizing and gives consultants accurate data for submittals.

Why the EKDM 3060 Suits Mega Projects

Large projects have problems that small projects never face. These include huge air volumes, long duct runs, strict codes, and zero tolerance for downtime. The EKDM 3060 is designed around those exact pressures.

Why Choose the Euroklimat EKDM 3060 Air Handling Unit Over Standard Units?

It balances extreme capacity, efficiency, and footprint. Instead of coordinating many mid-size units, engineers can design around fewer high-capacity units. That approach can simplify controls, reduce plant room clutter, and make maintenance more predictable.

Factor

Typical Standard AHU

EKDM 3060

Airflow capacity

Limited for mega-scale loads

Rated 300,000 m³/h

Cooling output

Often requires multiple units

2980 kW (~848 TR) in one unit

Casing performance

Thermal bridging is common

Thermal bridge-free design

Air leakage

Varies by build quality

0.02% at −1000 Pa

Filtration

Basic primary filters

Primary + bag filters, optional HEPA

Exhaust handling

Often a separate system

Built-in Super Exhaust function

Certification

Varies by manufacturer

AHRI and EUROVENT certified

Scalability

Fixed configuration

Modular sections for upgrades

Takeaway: When a project needs huge airflow plus sterile-grade air quality, the EKDM 3060 delivers both in one platform.

Applications: Where the Euroklimat AHU Performs Best

This unit fits sectors where air volume, cleanliness, and reliability can’t be compromised.

  • Hospitals and operating theaters (OTs): Sterile air supply, pressure control, and HEPA-ready filtration for surgical environments.
  • Pharmaceutical plants: Controlled clean air for production, packaging, and quality-sensitive processes.
  • Airports and metro stations: Large-scale ventilation and comfort cooling for high-traffic terminals and concourses.
  • Industrial facilities: Manufacturing halls, cleanrooms, and data centers that need steady temperature and humidity.
  • Commercial complexes: Malls, hotels, and mega offices where indoor air quality (IAQ) shapes the visitor and employee experience.

IAQ and Sterility Benefits for Critical Environments

Clean air is a safety requirement in hospitals and pharma plants, not a luxury. The EKDM 3060 supports IAQ compliance in several ways.

First, multi-stage filtration captures dust, pollen, and fine particles before they reach occupied spaces. Second, the low-leakage casing makes sure air goes through the filters instead of around them. Third, the Super Exhaust function helps maintain correct room pressures, which limits cross-contamination between zones.

Together, these features help facilities meet strict hygiene standards and protect patients, staff, and products.

Energy Efficiency and Operating Cost Control

Running a mega-capacity unit 24 hours a day makes efficiency a major cost factor. The Euroklimat AHU tackles this with optimized fans, high-efficiency coils, and low-conductivity insulation.

For a 2980 kW Air Handling Unit, even small efficiency gains add up to meaningful savings over a year of operation. Accurate sizing through selection software prevents energy waste from oversized equipment. Smart controls let fans and valves respond to actual demand instead of running at full output all the time.

This energy-conscious design also supports modern sustainability goals and green building targets.

Durability and Long Service Life

Mega projects need equipment that lasts. The aluminum alloy frame resists deformation. The thermal bridge-free casing prevents the condensation that often causes corrosion. Copper coils with rust-resistant fins hold up in humid conditions.

Modular construction also extends the system’s useful life. As a facility grows or its needs change, sections can be added, upgraded, or reconfigured without replacing the whole unit.

Common Mistakes When Specifying a Mega-Capacity AHU

Even strong equipment underperforms when it’s specified poorly. Watch for these errors:

  • Sizing by rule of thumb. Better approach: use detailed load calculations and manufacturer selection software.
  • Ignoring static pressure. Better approach: account for duct length, filter grade, and fittings so the fans can deliver the rated airflow.
  • Treating filtration as an afterthought. Better approach: match the filter stages to the application, especially for OTs and cleanrooms.
  • Overlooking plant room access. Better approach: plan clearances for coil cleaning, filter changes, and fan maintenance from day one.
  • Choosing a supplier on price alone. Better approach: pick a partner with proven installation, commissioning, and after-sales support.

Workman Services: Your Trusted Air Handling Unit Supplier

The right equipment needs the right partner. Choosing an experienced Air Handling Unit Supplier matters as much as choosing the unit itself.

Since 2006, Workman Services has delivered advanced HVAC&R and fire fighting solutions across residential, commercial, industrial, healthcare, office, and retail sectors. Our designers, qualified sales engineers, and certified technicians handle the full project cycle:

  1. Sales and consultation: Matching the right AHU to your load and air quality needs.
  2. Planning and coordination: Working with consultants, MEP teams, and contractors.
  3. Supply: Sourcing genuine equipment from quality brands.
  4. Installation: Professional mounting, ducting, and piping connections.
  5. Testing and commissioning: Verifying airflow, pressure, and control performance.
  6. Maintenance and support: Ongoing service to protect your investment.

Our portfolio includes HVAC and firefighting work at major sites such as Nishat Galleria Mall, Seran Packages, Dolmen Mall outlets, and Giga Mall. We also install VRF systems, chillers, FCUs, TFA units, and ducting, so your AHU integrates smoothly with the wider HVAC system.

With branches in Lahore, Rawalpindi, Faisalabad, and Abu Dhabi, we support projects across Pakistan and the UAE. Call +92 306 4410583 or email info@workmanservices.com.pk to discuss your project.

Frequently Asked Questions

What is the cooling capacity of the 2980 kW Air Handling Unit in tons?

It delivers about 848 TR. That figure comes from converting 2980 kW to roughly 10,170,000 BTU/hr and dividing by 12,000.

Is the Euroklimat AHU certified?

Yes. The EKDM 3060 is AHRI and EUROVENT certified, two globally recognized standards for performance and reliability.

Which projects need an Industrial Air Handling Unit of this size?

Projects that need very high airflow and strict air quality, such as airports, metro stations, hospitals, pharmaceutical plants, large factories, data centers, malls, and mega offices.

Can the Euroklimat Air Handling Unit be used in operating theaters?

Yes. With optional HEPA filtration, a 0.02% leakage rate, and the Super Exhaust function for pressure control, it suits sterile surgical environments.

How do I choose an Air Handling Unit Supplier for a large project?

Look for proven project experience, certified technicians, in-house design support, and complete installation, commissioning, and maintenance services.

What does the Super Exhaust function do?

It adds dedicated exhaust capability that removes stale or contaminated air and helps keep correct pressure relationships between rooms.

What filters does the EKDM 3060 use?

It uses pleated primary filters and medium-efficiency bag filters as standard, with optional HEPA filters for cleanrooms and OTs.

What are the chilled water requirements?

The unit needs a water flow rate of 65 to 84.5 L/s through DN 80 pipe connections.

Can the unit be expanded later?

Yes. Its modular sections allow you to add or upgrade cooling, heating, humidification, and filtration functions as needs change.

Final Thoughts

The EKDM 3060 brings mega-scale capacity, sterile-grade air quality, and long-term durability together in one modular platform. With 300,000 m³/h of rated airflow, 2980 kW of cooling, a thermal bridge-free casing, and AHRI and EUROVENT certification, it meets the demands of the most critical facilities. Pair it with expert design, installation, and commissioning, and you get a system built to perform for years.

Planning a hospital, pharma plant, airport, or large commercial project? Contact Workman Services today for a technical consultation and a project-specific quotation.

Reviews

There are no reviews yet.

Be the first to review “Euroklimat Air Handling Unit (Cooling Capacity 2980 kW) 848 TON”

Your email address will not be published. Required fields are marked *